For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

52.5 + 10 MFD

52.5_10
Note: Not all installations have two (2) wires connected to the common as shown in the dual-value illustrated examples. In some installations there is only one (1) wire which is common to the compressor and fan motor.

EXAMPLE: To replace a 52.5 + 10 microfarad
Dual-Value Capacitor: BEFORE YOU START: Make note of the wires which are
attached to the fan motor (F), common (C), and compressor (Herm) terminals of
the capacitor being replaced. STEP 1: To achieve the 52.5 microfarad for the
compressor (HERM) - using three (3) jumper wires (a) connect the 2.5 (3.0) + 5
(4), then (b) connect 5 (6) + 25, then (c) connect 25 + 20.  This will equal 52.5 microfarads. Connect one
of the wires from the compressor to the 25 MFD terminal. STEP 2: Connect the
other wire(s) from the compressor to the common (C). [The common is the center
black terminal]. STEP 3:  Connect one of
the fan wires to the 10.0 mfd terminal. STEP 4: Connect the other wire from the
fan motor to the common (C). [The common is the center black terminal].