For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

40.0 MFD

Default

EXAMPLE: To replace a 40.0
microfarad single value capacitor:

STEP 1: To obtain the 40.0 microfarad for the compressor (HERM), using two (2)
jumper

wires, (a) connect the 5 (4) + 10 then (b) connect the 10 + 25. This will equal
40.0 microfarads.

STEP 2: Connect one of the
compressor wires to the 25 MFD terminal.

STEP 3: Connect the other wire from the compressor motor to the common (C).
[The

common is the center black terminal].