For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

42.5 MFD

42.5

EXAMPLE: To replace a 42.5
microfarad single value capacitor:

STEP 1: To obtain the 42.5 microfarad for the compressor (HERM), using three (3)
jumper

wires, (a) connect the 2.5 (3.0) + 5 (4) then (b) connect the 2.5 (3.0) +10,
then (c) connect the 10 + 25. This will equal 42.5 microfarads.

STEP 2: Connect one of the
compressor wires to the 25 MFD terminal.

STEP 3: Connect the other wire from the compressor motor to the common (C).
[The

common is the center black terminal].