For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

45.0 MFD

45

EXAMPLE: To replace a 45.0
microfarad single value capacitor:

STEP 1: To obtain the 45.0 microfarad for the compressor (HERM), using one (1)
jumper

wire, connect the 20 + 25. This will equal 45.0 microfarads.

STEP 2: Connect one of the
compressor wires to the 25 MFD terminal.

STEP 3: Connect the other wire from the compressor motor to the common (C).
[The