For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

52.5 MFD

52.5

EXAMPLE: To replace a 52.5
microfarad single value capacitor:

STEP 1: To obtain the 52.5 microfarad for the compressor (HERM), using three (3)
jumper

wires, (a) connect the 2.5 (3.0) + 5 (6) then (b) connect the 5 (6) +25, then
(c) connect the 25 + 20. This will equal 52.5 microfarads.

STEP 2: Connect one of the
compressor wires to the 25 MFD terminal.

STEP 3: Connect the other wire from the compressor motor to the common (C).
[The
common is the center black terminal].