For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

57.5 MFD

57.5

EXAMPLE: To replace a 57.5
microfarad single value capacitor:

STEP 1: To obtain the 57.5 microfarad for the compressor (HERM), using three (3)
jumper
wires, (a) connect the 2.5 (3.0) + 10, then (b) connect the 10 + 20, then (c)
connect the 20 + 25. This will equal 57.5 microfarads.

STEP 2: Connect one of the
compressor wires to the 25 MFD terminal.

STEP 3: Connect the other wire from the compressor motor to the common (C).
[The
common is the center black terminal].