For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

62.5 MFD

62.5

EXAMPLE: To replace a 62.5
microfarad single value capacitor:

STEP 1: To obtain the 62.5 microfarad for the compressor (HERM), using four (4)
jumper
wires, (a) connect the 2.5 (3.0) + 5 (4), then (b) connect the 2.5 (3.0) + 10,
then (c) connect the 10 + 20, then (d) connect 20 + 25. This will equal 62.5
microfarads.

STEP 2: Connect one of the
compressor wires to the 25 MFD terminal.

STEP 3: Connect the other wire from the compressor motor to the common (C).
[The
common is the center black terminal].