For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

67.5 MFD

67.5

EXAMPLE: To replace a 67.5
microfarad single value capacitor:

STEP 1: To obtain the 62.5 microfarad for the compressor (HERM), using five (5)
jumper
wires, (a) connect the 5 (6) + 5 (4), then (b) connect the 5 (4) + 2.5 (3.0),
then (c) connect the 2.5 (3.0) + 10, then (d) connect the 10 + 20, then (e)
connect 20 + 25. This will equal 67.5 microfarads.

STEP 2: Connect one of the
compressor wires to the 25 MFD terminal.

STEP 3: Connect the other wire from the compressor motor to the common (C).
[The