For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

20 + 3 MFD

20_3
Note: Not all installations have two (2) wires connected to the common as shown in the dual-value illustrated examples. In some installations there is only one (1) wire which is common to the compressor and fan motor.

EXAMPLE:
To replace a 20 + 3.0 microfarad Dual-Value Capacitor: BEFORE YOU START:
Make note of the wires which are attached to the fan motor (F), common (C), and
compressor (Herm) terminals of the capacitor being replaced. STEP 1: To achieve
the 20.0 microfarad for the compressor (HERM) - Connect one of the wires from
the compressor to the 20 MFD terminal. STEP 2: Connect the other wire(s) from
the compressor to the common (C). [The common is the center black terminal].
STEP 3: Connect one of the fan wires to the 2.5 (3.0)  MFD terminal.
STEP 4: Connect the other wire from the fan motor to the common (C). [The
common is the center black terminal].