Turbo 200 Wiring Installation Instructions

20 + 7.5 MFD

20_7.5
Note: Not all installations have two (2) wires connected to the common as shown in the dual-value illustrated examples. In some installations there is only one (1) wire which is common to the compressor and fan motor.

EXAMPLE:
To replace a 20 + 7.5 microfarad Dual-Value Capacitor: BEFORE YOU START:
Make note of the wires which are attached to the fan motor (F), common (C), and
compressor (Herm) terminals of the capacitor being replaced. STEP 1: To achieve
the 20.0 microfarad for the compressor (HERM) - Connect one of the wires from
the compressor to the 20 MFD terminal. STEP 2: Connect the other wire(s) from
the compressor to the common (C). [The common is the center black terminal]. STEP
3: To obtain the 7.5 microfarad for the fan (F), using one (1) jumper wire
connect the 5 (4) + 2.5 (3.0). This will equal 7.5 microfarads. STEP 4: Connect one of the fan wires
to the 5.0 (4.0) MFD terminal. STEP 4: Connect the other wire from the fan
motor to the common (C). [The common is the center black terminal].