For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

22.5 + 6 MFD

22.5_6
Note: Not all installations have two (2) wires connected to the common as shown in the dual-value illustrated examples. In some installations there is only one (1) wire which is common to the compressor and fan motor.

EXAMPLE: To replace a 22.5 + 6 microfarad
Dual-Value Capacitor: BEFORE YOU START: Make note of the wires which are
attached to the fan motor (F), common (C), and compressor (Herm) terminals of
the capacitor being replaced. STEP 1: To achieve the 22.5 microfarad for the
compressor (HERM) - Using one (1) jumper wire, connect the 20 + 2.5 (3.0).  This will equal 22.5 microfarads.  STEP 2: Connect one of the wires from the
compressor to the 20 MFD terminal. STEP 3: Connect the other wire(s) from the
compressor to the common (C). [The common is the center black terminal]. STEP 4:
To obtain the 6.0 microfarad for the fan (F), connect one of the fan wires to
the 5 (6) MFD terminal. STEP 4: Connect the other wire from the fan motor to
the common (C). [The common is the center black terminal].