For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

30 + 5 MFD

30_5
Note: Not all installations have two (2) wires connected to the common as shown in the dual-value illustrated examples. In some installations there is only one (1) wire which is common to the compressor and fan motor.

EXAMPLE: To replace a 30.0 + 5.0 microfarad Dual-Value Capacitor: BEFORE
YOU START: Make note of the wires which are attached to the fan motor (F),
common (C), and compressor (Herm) terminals of the capacitor being replaced.
STEP 1: To achieve the 30.0 microfarad for the compressor (HERM) - using one
(1) jumper wire connect the 20 + 10. This will equal 30.0 microfarads. Connect
one of the wires from the compressor to the 20 MFD terminal. STEP 2: Connect
the other wire(s) from the compressor to the common (C). [The common is the
center black terminal]. STEP 3: Connect one of the fan wires to the 5.0
(6.0) MFD terminal. STEP 4: Connect the other wire from the fan motor to the
common (C). [The common is the center black terminal].