For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

35 + 3 MFD

35_3
Note: Not all installations have two (2) wires connected to the common as shown in the dual-value illustrated examples. In some installations there is only one (1) wire which is common to the compressor and fan motor.

To replace a 35 + 3 microfarad Dual-Value Capacitor: 

BEFORE YOU START: Make note of the wires which are attached to the fan motor (F), common (C), and compressor (Herm) terminals of the capacitor being replaced. 

STEP 1: To achieve the 35.0 microfarad for the compressor (HERM) - using one (1) jumper wire connect the 25 + 10. This will equal 35.0 microfarads. Connect one of the wires from the compressor to the 25 MFD terminal. 

STEP 2: Connect the other wire(s) from the compressor to the common (C). [The common is the center black terminal]. 

STEP 3: Connect one of the fan wires to the 2.5 (3.0) MFD terminal. STEP 4: Connect the other wire from the fan motor to the common (C). [The common is the center black terminal].