For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

35 + 10 MFD

35_10
Note: Not all installations have two (2) wires connected to the common as shown in the dual-value illustrated examples. In some installations there is only one (1) wire which is common to the compressor and fan motor.

EXAMPLE: To replace a 35 + 10.0 microfarad
Dual-Value Capacitor: BEFORE YOU START: Make note of the wires which are
attached to the fan motor (F), common (C), and compressor (Herm) terminals of
the capacitor being replaced. STEP 1: To achieve the 35.0 microfarad for the
compressor (HERM) - using one (1) jumper wire connect the 25 + 10. This will
equal 35.0 microfarads. Connect one of the wires from the compressor to the 25
MFD terminal. STEP 2: Connect the other wire(s) from the compressor to the
common (C). [The common is the center black terminal]. STEP 3: To obtain
the 10.0 microfarad for the fan (F), using one (1) jumper wire connect the 5 (4)
+ 5 (6). This will equal 10.0 microfarads. STEP 4: Connect one of the fan wires
to the 5.0 (6.0) MFD terminal. STEP 5: Connect the other wire from the fan
motor to the common (C). [The common is the center black terminal].