For Turbo200X Wiring Instructions Click Here

Turbo 200 Wiring Installation Instructions

45 + 12.5 MFD

45_12.5
Note: Not all installations have two (2) wires connected to the common as shown in the dual-value illustrated examples. In some installations there is only one (1) wire which is common to the compressor and fan motor.

EXAMPLE: To replace a 45.0 + 12.5 microfarad Dual-Value Capacitor: BEFORE
YOU START: Make note of the wires which are attached to the fan motor (F),
common (C), and compressor (Herm) terminals of the capacitor being replaced.
STEP 1: To achieve the 45.0 microfarad for the compressor (HERM) - using one (1)
jumper wire (a) connect the 25 + 20.  This
will equal 45.0 microfarads. Connect one of the wires from the compressor to
the 25 MFD terminal. STEP 2: Connect the other wire(s) from the compressor to
the common (C). [The common is the center black terminal]. STEP 3: Using
one (1) jumper wire connect the 2.5 (3.0) + 10.  This will equal 12.5 microfarads. STEP 4: Connect
one of the fan wires to the 10.0 MFD terminal. STEP 5: Connect the other wire
from the fan motor to the common (C). [The common is the center black
terminal].